Model AD-26P Model AD-56P Model AD-27P Model AD-57P
Supply Voltage 12 VDC 24 VDC 120VAC, 240 VAC,
50/60Hz 50/60Hz
Audio Power Output
(Max.) 8.0 Watts 11.7 Watts 11.3 Watts 11.3 Watts
Power Consumption
(Max.) 20.0 Watts 39.6 Watts 28.8 Watts 30.5 Watts
Operating Current
(Nominal) 1.47A 1.65A 0.240A 0.127A
Operating Temperature -31
°
F to 150
°
F
Shipping Weight 2 lb. 1.5 oz. 2 lb. 1.5 oz. 2 lb. 11.6 oz. 2lb. 11.6 oz.
Dimensions See Figure 1
Ratings UL, cUL (Recognized Component Listing)
Table 1
Additional Model Information
Letter Group Function / Feature
“A” Call button
“C” Master mode
“D” Slave mode
Number Group
“-1” Remote power
“-8” Additional pre-amp for use with
remote slave speaker
Miscellaneous
“-M44” Remote speaker volume control
Table 2
MASTER UNITS:
“C” Models default to Master, or speaker mode. In Master mode, the unit acts as a speaker and
broadcasts audio signals generated elsewhere in the intercom system. Depressing the Talk
switch turns the unit into a microphone and enables the user to broadcast to all other intercoms
in the system. Releasing the switch returns the unit to Master mode. Figures 2 through 4
illustrate Master/Slave intercom systems.
SLAVE UNITS:
“D” Models default to Slave, or microphone, mode. In Slave mode, the unit is designed to serve
as a hands-free microphone with transmission to all Master units in the intercom system. The
Slave unit will act as a speaker and broadcast audio transmissions only when the Talk switch of
any Master unit in the intercom system is depressed. Figures 2 through 4 illustrate Master/Slave
intercom systems.